Every dome run is checked for click force, dimensions and contact, with life-cycle testing for high-use keypads. That is how the feel stays the same from your first order to your tenth.

A dome has to feel right, fit right, conduct cleanly and last. We test all four, run by run.
Each key is measured along its full force-travel curve: peak force, contact force, snap ratio and return force, with the batch average and spread on the report.
Diameter, height and footprint measured on a video measuring system against your drawing, so domes seat on your pads. Standard tolerances are ±0.10 mm on diameter and ±0.05 mm on height.
Resistance through the dome to the circuit is measured on our test fixture against a limit of 1 Ω or less on standard domes, batch by batch.
Each dome is life-tested against its rated cycles, 500,000 to 1,000,000 on standard domes, and high-use designs are validated to several million actuations before they go to volume. The tester presses the dome center with a 2.0 mm flat copper probe at 1.5 times the rated force, 120 times a minute, as our metal dome life testing guide describes.
We press each metal dome with a servo-driven probe on an automatic force-curve tester and record force against travel, going down and coming back up. The probe has a 0.75 mm radius ball tip and lands on the dome center within a 0.4 mm position tolerance, so readings repeat from dome to dome. From each curve we read the peak force, the contact force, the return force and the travel at each point, then report the batch average and spread. Our guide to reading actuation force and travel explains each point.
Past the contact point the curve climbs steeply as the dome bottoms out on the board, which is why every trace turns almost vertical after F2.
| Key | F1 peak (gf) | F2 contact (gf) | Snap ratio | F3 return (gf) |
|---|---|---|---|---|
| 1 | 240.2 | 116.9 | 51.3% | 72.1 |
| 2 | 225.2 | 96.1 | 57.3% | 68.4 |
| 3 | 250.2 | 123.2 | 50.8% | 83.2 |
| 4 | 272.1 | 113.3 | 58.4% | 64.5 |
| 5 | 231.5 | 129.3 | 44.2% | 72.8 |
| 6 | 249.4 | 164.9 | 33.9% | 99.3 |
| Average | 244.8 | 124.0 | 49.3% | 76.7 |
| Std. deviation | 16.6 | 23.0 | 9.1 | 12.7 |
Your parts get the same report: each key's curve and readings, with the batch maximum, minimum, range, average and standard deviation, checked against the target force on your approved sample. This example is one report from 2016, shown to explain the method rather than as a specification; your force target and tolerance are set on your own drawing.

Quality is built in at each step rather than checked only at the end. Incoming stainless is verified, the press is set against an approved sample, force is measured during the run, and a final inspection clears the lot before packing.
What matters to a switch maker is that reorders match the first run. We hold the force, the contact and the dimensions to your approved sample, and we keep the tooling and the test fixture so the next batch starts from the same baseline.
Your signed-off sample is the reference every later run is measured against.
Tooling and test fixtures are kept, so reorders repeat the same build.
Click force checked to your target on every production run.
Sample reports with force, dimensions and drawing, a COA with each batch, plus RoHS and REACH reports and MSDS on request. Plating can be held to the ASTM or GB standard your drawing names.
A keypad in a medical cart, a boat helm or a factory floor sees moisture, salt and heat that a bench test never does. We test metal domes for the conditions they will work in, and we back the material with third-party reports.
Plated domes pass a 24 or 48 hour neutral salt spray (NSS) test as standard, with no visible rust, blistering or peeling on the contact face. A thicker plating or a sealing treatment takes it to 72 or 96 hours.
Gold- and nickel-plated domes work continuously from -40 °C to +125 °C, with short peaks to +150 °C. Silver-plated domes are rated -40 °C to +85 °C, because heat speeds up tarnish. Dome arrays are limited by the film and adhesive: -20 °C to +85 °C as standard, or -40 °C to +105 °C with high-temperature PET and adhesive.
Humidity testing checks the contact and the plating in the damp, warm conditions where corrosion starts.
ISO 9001, ISO 13485 for medical devices and IATF 16949 for automotive parts, with certificates, third-party RoHS and REACH reports and MSDS available on request.
Every batch has its plating measured for thickness and tested for adhesion before it ships, and a COA can travel with the goods.
Typical thickness, contact resistance and cost for each finish are compared in our metal dome plating guide.
Tell us the shape, size, force and life target. We confirm the build on an approved sample before mass production.