OEM / ODM metal domes & snap domes|Made to your drawing
Foshan, China|+86 757 7323 4892|sales@inoxdome.com
Home/Quality
Quality

Tested for force, feel and life.

Every dome run is checked for click force, dimensions and contact, with life-cycle testing for high-use keypads. That is how the feel stays the same from your first order to your tenth.

Close-up of metal domes on a membrane switch flex circuit
Checked every runForce · contact · life cycle
What we check

The four things that make a dome reliable.

A dome has to feel right, fit right, conduct cleanly and last. We test all four, run by run.

Force

Click force

Each key is measured along its full force-travel curve: peak force, contact force, snap ratio and return force, with the batch average and spread on the report.

Fit

Dimensions

Diameter, height and footprint measured on a video measuring system against your drawing, so domes seat on your pads. Standard tolerances are ±0.10 mm on diameter and ±0.05 mm on height.

Contact

Contact resistance

Resistance through the dome to the circuit is measured on our test fixture against a limit of 1 Ω or less on standard domes, batch by batch.

Life

Life cycle

Each dome is life-tested against its rated cycles, 500,000 to 1,000,000 on standard domes, and high-use designs are validated to several million actuations before they go to volume. The tester presses the dome center with a 2.0 mm flat copper probe at 1.5 times the rated force, 120 times a minute, as our metal dome life testing guide describes.

Method

How do we measure click force?

We press each metal dome with a servo-driven probe on an automatic force-curve tester and record force against travel, going down and coming back up. The probe has a 0.75 mm radius ball tip and lands on the dome center within a 0.4 mm position tolerance, so readings repeat from dome to dome. From each curve we read the peak force, the contact force, the return force and the travel at each point, then report the batch average and spread. Our guide to reading actuation force and travel explains each point.

Force-travel curves for six metal dome keys, with peak force, contact force and return force marked on key 1
Six keys from one production force report, traced from the tester output; key 1 marked

What the four readings mean

  • F1, peak force: the highest point before the dome snaps. This is the click force you specify, in grams-force.
  • F2, contact force: the low point after the snap, where the dome center reaches the contact pad and the switch closes.
  • Snap ratio: (F1 - F2) / F1. A bigger drop gives a crisper click; on key 1 above it is 51%.
  • F3, return force: the force pushing the key back up on release. Too little and a key can stick down.

Past the contact point the curve climbs steeply as the dome bottoms out on the board, which is why every trace turns almost vertical after F2.

The numbers from that report

KeyF1 peak (gf)F2 contact (gf)Snap ratioF3 return (gf)
1240.2116.951.3%72.1
2225.296.157.3%68.4
3250.2123.250.8%83.2
4272.1113.358.4%64.5
5231.5129.344.2%72.8
6249.4164.933.9%99.3
Average244.8124.049.3%76.7
Std. deviation16.623.09.112.7

Your parts get the same report: each key's curve and readings, with the batch maximum, minimum, range, average and standard deviation, checked against the target force on your approved sample. This example is one report from 2016, shown to explain the method rather than as a specification; your force target and tolerance are set on your own drawing.

Close inspection of a metal dome on a circuit
Inspection flow

Checks from incoming steel to pack-out.

Quality is built in at each step rather than checked only at the end. Incoming stainless is verified, the press is set against an approved sample, force is measured during the run, and a final inspection clears the lot before packing.

  • Incoming material check on the stainless steel
  • First-article approval against your signed-off sample
  • In-process force checks during the run
  • Final inspection and force test before pack-out
  • Vacuum moisture-barrier packing with desiccant and a humidity indicator card; silver-plated domes are also wrapped in sulfur-free paper
  • A corrective action report with the cause and the fix if a lot misses spec
Consistency

The same dome, order after order.

What matters to a switch maker is that reorders match the first run. We hold the force, the contact and the dimensions to your approved sample, and we keep the tooling and the test fixture so the next batch starts from the same baseline.

01

Approved sample

Your signed-off sample is the reference every later run is measured against.

02

Held tooling

Tooling and test fixtures are kept, so reorders repeat the same build.

03

Force per spec

Click force checked to your target on every production run.

04

Documentation

Sample reports with force, dimensions and drawing, a COA with each batch, plus RoHS and REACH reports and MSDS on request. Plating can be held to the ASTM or GB standard your drawing names.

Environment & compliance

Salt spray, temperature and damp heat testing.

A keypad in a medical cart, a boat helm or a factory floor sees moisture, salt and heat that a bench test never does. We test metal domes for the conditions they will work in, and we back the material with third-party reports.

01

Salt spray

Plated domes pass a 24 or 48 hour neutral salt spray (NSS) test as standard, with no visible rust, blistering or peeling on the contact face. A thicker plating or a sealing treatment takes it to 72 or 96 hours.

02

High and low temperature

Gold- and nickel-plated domes work continuously from -40 °C to +125 °C, with short peaks to +150 °C. Silver-plated domes are rated -40 °C to +85 °C, because heat speeds up tarnish. Dome arrays are limited by the film and adhesive: -20 °C to +85 °C as standard, or -40 °C to +105 °C with high-temperature PET and adhesive.

03

Damp heat

Humidity testing checks the contact and the plating in the damp, warm conditions where corrosion starts.

04

Certification

ISO 9001, ISO 13485 for medical devices and IATF 16949 for automotive parts, with certificates, third-party RoHS and REACH reports and MSDS available on request.

Plating

How is the plating checked on every batch?

Every batch has its plating measured for thickness and tested for adhesion before it ships, and a COA can travel with the goods.

  • Thickness: an X-ray fluorescence (XRF) gauge measures the nickel underlayer and the gold or silver top layer at several points on the center contact and the legs, without damaging the dome.
  • Tape test: a high-tack test tape such as 3M 600 is pressed onto the plating and pulled off sharply; no plating may lift or flake.
  • Bend test: sample domes are bent through 90 to 180 degrees until the steel breaks, and the fracture is checked under a microscope for blistering or separation.
  • Thermal shock or bake: samples are cycled between -40 °C and +125 °C, or baked at 200 °C for one hour, then checked for discoloration, blistering or loss of adhesion.
  • Storage: unopened and kept at 15 to 25 °C below 60% RH, gold-plated domes keep for 24 months or more, and nickel- and silver-plated domes for 6 to 12 months.

Typical thickness, contact resistance and cost for each finish are compared in our metal dome plating guide.

Request a quote

Send your spec and force target.

Tell us the shape, size, force and life target. We confirm the build on an approved sample before mass production.